• Pressure Drop Chart - Temporary Cone and Basket Strainers ...

    PRESSURE DROP CHART Temporary Cone and Basket Strainers (TC, TB) KECKLEY This pressure drop chart is based on the flow of clean water through the Keckley Strainer Styles listed above with screen perforations ranging from 1/16” through 1/8”. TO USE CHARTS: Find your desired rate of flow (GPM) on the left hand side of the chart.

  • 文件大小: 32KB
  • Pressure Drop Online Calculator PDA

    Pressure Drop Online Calculator for Mobile and PDA-----Element of pipe: Strainers and grids / Conical strainer

  • Engineering Specification for the Selection, Installation ...

    A temporary strainer is also an option. Only low net open areas are available with this type of strainer. In addition, operating pressure drops are normally higher and maximum allowable pressure drops lower than with other types of strainers. Figure 11 . For applications where continuous operation is required, a scraper strainer provides removal

  • 文件大小: 710KB
  • Estimate Clean Pressure Drop in Cone Strainer - Chemical ...

    Apr 25, 2006  Here is an old approximation for a clean strainer where a cone is equal to 100% of the pressure drop for same. A truncated cone is 80% of the value. Pressure Drop (psi)= .0005*P*V^2 P= density = #/ft^3 V=fluid velocity of approach in ft/sec This is taken from an old Mack Iron Works Chart

  • Here is an old approximation for a clean strainer where a cone is equal to 100% of the pressure drop for same. A truncated cone is 80% of the value...I would model the wire mesh and the perf as multiple orifices in parallel. The perf is easy enough, round holes with square edges, known thickness,[email protected]: And, as MikeHalloran suggests, if you do set it up in a standpipe and do a water flow test, you may please post your observations and recor...Thanks guys, A test stand probably won't be practical, but I should be able to get clean dP data under recycle gas circulation as a prestart-up act...The approximation is for comparisons to a conical strainer of length L. Truncated cone 175% vol; 150% area; 80% pressure drop at length L Inverted...Gentlemen, I contacted the designer to give me an estimated pressure drop for this service. His answer was 2 to 3psid clean pressure drop for the n...
  • Temporary Strainers And Custom Screens Catalogue

    Custom Engineered Strainers, Screens and Baskets Quad Reverse Cone Strainer Production Capabilities and Engineering Expertise Temporary Cone and Basket Strainers Features Ordering Information Dimensional Data Fabricated Tee Type Strainers Construction Dimensional Data Pressure Drop Charts Custom Strainer Styles Fabricated Basket Strainers

  • 文件大小: 2MB
  • Calculate Pressure Drop in Strainers

    Sample Sure Flow Y-strainer calculation Estimate pressure drop across 100 mesh lined Sure Flow Y-strainer provided in a 6″ line with following data. • Flow rate = 700 GPM • Viscosity = 100 cP • Specific Gravity = 0.80 • 100 mesh screen The Pressure Drop Chart for Y-strainer indicates a drop of 1.3 psi.

  • Temporary Strainers Cone Strainers Weamco

    Temporary Strainers Weamco (The First Name in Strainers) has been manufacturing dependable high quality Permanent and Temporary Strainers since 1973. Industries such as Pipelines, Hydrocarbon, Chemical, Power, Gas, Pulp Paper, Process Plants, and Refineries all over the world have come to depend on Weamco's impeccable service, quality and ...

  • Strainer pressure drop calculator - EnggCyclopedia

    This application can be used to estimate the pressure drop across a strainer with a standard mesh for given strainer size and liquid flow. Strainer size 0.5"0.75"1"1.25"1.5"2"3"4"5"6"8"10"12"14"16"18"20"24" inches Liquid volumetric flowrate m3/hr Liquid density kg/m3 Liquid viscosity (Select the nearest value) 1102510020050010002000 cP Strainer pressure drop bar

  • Temporary Strainer - piping-designer

    As an example, the downstream pressure should never fall below the NPSHr of a pump. Perforation size or screen size. The strainer should be slightly smaller than the smallest piece of debris that is expected to flow through it. If the perforations are too small, a high pressure drop could develop across the strainer and cause it to fail.

  • PRESSURE DROP CHARTS - WYE BASKET STRAINERS

    PRESSURE DROP CHARTS f WYE BASKET STRAINERS TITAN TITAN FLOW CONTROL, INC. Tel: 910-735-0000 s Fax: 910-738-3848 s [email protected] titanfci 290 Corporate Drive s PO Box 7408 s Lumberton, NC 28358 TITAN FLOW CONTROL, INC. Cv CORRECTION FACTOR TABLE Centistokes (SSU) Perf. (Unlined) 20 MESH 40 MESH 60 MESH 80 MESH 100 MESH 120 MESH ...

  • Calculate Pressure Drop in Strainers

    Sample Sure Flow Y-strainer calculation Estimate pressure drop across 100 mesh lined Sure Flow Y-strainer provided in a 6″ line with following data. • Flow rate = 700 GPM • Viscosity = 100 cP • Specific Gravity = 0.80 • 100 mesh screen The Pressure Drop Chart for Y-strainer indicates a drop of 1.3 psi.

  • Calculate Pressure Drop in Filters and Strainers ...

    Estimate pressure drop across 100 mesh lined Basket Type strainer provided in a 6″ line with following data. Flow rate = 700GPM Viscosity = 100cP Specific Gravity = 1 The Pressure Drop Chart for Basket strainers indicates a drop of 0.9psi. The Screen openings chart indicates the

  • Pressure Drop Curves for Y-Type Strainers - Fabrotech

    Pressure Drop Curve graphs for Y-Type Strainers. Pressure Drop Curves for "Y" Type Strainers. FABROTECH INDUSTRIES, INC. 2089 Ninth Ave. Ronkonkoma, NY 11779 Telephone (631) 467-2040 Secondary (631) 467-2046 Fax (631) 467-2196 1-800-313-0153

  • Conical Strainer Pressure Drop - Pump engineering - Eng-Tips

    Dec 22, 2005  Conical Strainer Pressure Drop Mech85 (Mechanical) (OP) 20 Dec 05 00:30. Hi, I'm am looking for typical pressure drops across DN 750 (30") and DN 600(24") conical strainers on a cooling water application. Flow rate is approx 2400m3/h (~10,000gpm). The strainers are fabricated from 3mm (1/8") perforated plate and the open area is 150% of line ...

  • Strainer pressure drop calculator - EnggCyclopedia

    This application can be used to estimate the pressure drop across a strainer with a standard mesh for given strainer size and liquid flow. Strainer size 0.5"0.75"1"1.25"1.5"2"3"4"5"6"8"10"12"14"16"18"20"24" inches Liquid volumetric flowrate m3/hr Liquid density kg/m3 Liquid viscosity (Select the nearest value) 1102510020050010002000 cP Strainer pressure drop bar

  • Piping Materials : Temporary Conical Strainers » The ...

    The expected pressure drop across the strainer should not cause the downstream operating pressure to fall below the minimum required pressure of the line e.g. NPSH for a pump. The perforations of the strainer should be slightly smaller than the smallest piece of debris that is expected to flow through it.

  • Keckley Company Fabricated Temporary Strainers

    Temporary basket strainers will have a slightly higher pressure loss across them than temporary cone strainers. Temporary plate strainers will have the highest pressure drop. Special reinforcing rings and supports can be installed to maintain integrity of the cone or basket for heavy load applications where the differential pressure will exceed ...

  • PRESSURE DROP CHARTS - WYE BASKET STRAINERS

    PRESSURE DROP CHARTS f WYE BASKET STRAINERS TITAN TITAN FLOW CONTROL, INC. Tel: 910-735-0000 s Fax: 910-738-3848 s [email protected] titanfci 290 Corporate Drive s PO Box 7408 s Lumberton, NC 28358 TITAN FLOW CONTROL, INC. Cv CORRECTION FACTOR TABLE Centistokes (SSU) Perf. (Unlined) 20 MESH 40 MESH 60 MESH 80 MESH 100 MESH 120 MESH ...

  • STR990-1 Pressure Drop Data Y - Colton Industries

    Strainer Size: 1-1/4" a) Using FIGURE 1 the pressure drop is determined to be 1.0 psid using the standard screen Filtration: 100 mesh lined 1/32" perf. b) Looking at the replacement screen data sheet, we find that the % open area of 100 mesh is 30%

  • Sure Flow Equipment Inc.

    Duplex Strainers. Automatic Backwash Strainers. Temporary Cone Strainers. Tee Type Strainers. Sanitary Strainers. Fabricated Strainers. Replacement Screens and Baskets. If it’s not in stock we will custom fabricate it! Learn More. Custom Engineered Strainers . Custom Strainers, Dual Baskets, Pressure Vessels Damper Valves. Whatever you need ...

  • Fabricated Temporary Strainer - Hellan Strainer

    Other materials, sizes and OAR conditions are available up on request. Pressure ranges up to 3,600 PSIG at 800 degrees F. Multiple flow options are available for each design, including inside to outside, outside to inside and bidirectional. Flow Rate vs Pressure Drop Accessories . Type TC Temporary Strainer In-Line Flow, Cone Geometry

  • TITAN TITAN FLOW CONTROL, INC.

    Once pressure is relieved and fluid is drained, loosen the flange bolts. Step 4: Remove flange gaskets. Step 5: Remove Startup Strainer from pipeline and replace with a permanent type strainer. SPARE PARTS LIST: Startup Strainers are designed for temporary service. As such, there are no spare parts. Once the piping system

  • Temporary Cone, Basket, and Flat type Strainers

    For ring type joint- specify ring number style. When ordering, the following information should be specified: 1) Pipe size, 2) Pressure rating, 3) Perforation or mesh size, 4) Material, 5) Style. Contact our engineering department for special designs or length. Cone Strainer

  • Cone Type Strainer Pressure Drop - EXART

    type 51-rtj type 50-p cone strainer . is added, multiply pressure drop in charts by: wrg winston / royal guard corporation 51-p basket strainer pressure drop chart flow rate of water - gpm (clean basket) - psi clean perforated basket with 1/8" diameter holes 40 mesh 60 mesh 80 mesh

  • Pressure Drop Curves for Y-Type Strainers - Fabrotech

    Pressure Drop Curve graphs for Y-Type Strainers. Pressure Drop Curves for "Y" Type Strainers. FABROTECH INDUSTRIES, INC. 2089 Ninth Ave. Ronkonkoma, NY 11779 Telephone (631) 467-2040 Secondary (631) 467-2046 Fax (631) 467-2196 1-800-313-0153

  • Keckley Company Fabricated Temporary Strainers

    Temporary basket strainers will have a slightly higher pressure loss across them than temporary cone strainers. Temporary plate strainers will have the highest pressure drop. Special reinforcing rings and supports can be installed to maintain integrity of the cone or basket for heavy load applications where the differential pressure will exceed ...

  • Fabricated Temporary Strainer - Hellan Strainer

    Other materials, sizes and OAR conditions are available up on request. Pressure ranges up to 3,600 PSIG at 800 degrees F. Multiple flow options are available for each design, including inside to outside, outside to inside and bidirectional. Flow Rate vs Pressure Drop Accessories . Type TC Temporary Strainer In-Line Flow, Cone Geometry

  • Pressure Drop Curves for Temporary Strainers

    Temporary Strainer Drawings and Pressure Drop Chart You can use the differential pressure chart to estimate the approximate clean pressure drop across a temporary cone or basket style strainer. The chart data is based upon water and perforations ranging from 1/8" to 1/16".

  • High Pressure Conical Gas Strainers TM Filtration

    These strainers are installed by sandwiching it between two flanges in a removable section of pipe, such as a spool piece. The differential pressure across this strainer should be monitored to indicate when the strainer should be removed from the system and cleaned. ... Drop us a line. Phone: 1.814.456.1448 Fax: 1.814.452.6573. Web ...

  • Cone Strainers Fluid Engineering

    The typical “witches hat” cone designs can be supplied, as well as the “pilgrim hat”, or basket-type strainer. Perforated strainers, mesh-lined strainers, and even specialty cones with anti-vibration rings are available upon request. Cone Strainers are typically supplied in 304 or 316 stainless steel but other materials are available.

  • STR990-1 Pressure Drop Data Y - Colton Industries

    Strainer Size: 1-1/4" a) Using FIGURE 1 the pressure drop is determined to be 1.0 psid using the standard screen Filtration: 100 mesh lined 1/32" perf. b) Looking at the replacement screen data sheet, we find that the % open area of 100 mesh is 30%

  • Permanent Strainers Temporary Strainers Weamco

    Weamco has been manufacturing dependable high quality permanent and temporary strainers since 1973.

  • Inko Engineering Supplies Pte Ltd

    Since the viscosity is 200 SSU, the corrected pressure drop = I .30 X I .30 2.69 psi Since there is an extra 40 mesh lined wire mesh, corrected pressure drop = 1.61 x 1.30 = 2.09 psi Sizing Y-strainer Correction fnetor: For liquids moro viseous than water or whom wire cloth Iinor added. pressure droo in charts by PerfMated w'Wire Cloth Attacnea ...

  • Introduction to Strainer in Piping - The Process Piping

    Oct 22, 2017  T type or Basket type or Pot type strainer is characterized by a vertically orientated chamber, typically larger than that of a Y-type strainer. Size for size, the pressure drop across a basket strainer is less than that across the Y-type as it has a greater free straining area, which makes the basket type strainer the preferred type for liquid ...

  • Simplex Strainers (Series 105, 105F, 107, and 115)

    Simplex Strainers (Series 105, 105F, 107, and 115) Cast simplex strainers are used in applications where the flow can be interrupted for basket cleaning. These strainers are an excellent choice for protection of pumps, meters, valves, traps, spray nozzles,

  • Guidelines for The Preparation of Strainer Specification ...

    8.4. For temporary cone type strainers break off flanges (spool piece) to be considered for ease in removal. 8.5. Temporary conical strainers are to be placed with the cone pointing opposite to the direction of flow. 9. Pressure Drop across a Strainer / Mesh Number

  • STR995-1 Pressure Drop Data Basket

    Strainer Size: 3" a) Using FIGURE 1 the pressure drop is determined to be 0.4 psid using the standard screen Filtration: 100 mesh lined 1/8" perf. b) Looking at the replacement screen data sheet, we find that the % open area of 100 mesh is 30%

  • Startup Strainers Temporary Strainers • Winston/Royal ...

    Winston/Royal Guard’s Type 50-P cone strainers and Type 51-P basket strainers, commonly called startup strainers or temporary strainers, are furnished extensively for use in new piping installations to catch such things as weld slag, pipe scale, and other unwanted solids.However, many times after initial cleaning the "temporary strainers" are placed back in service for permanent protection ...

  • High Pressure Conical Gas Strainers TM Filtration

    These strainers are installed by sandwiching it between two flanges in a removable section of pipe, such as a spool piece. The differential pressure across this strainer should be monitored to indicate when the strainer should be removed from the system and cleaned. ... Drop us a line. Phone: 1.814.456.1448 Fax: 1.814.452.6573. Web ...

  • Guidelines for The Preparation of Strainer Specification ...

    8.4. For temporary cone type strainers break off flanges (spool piece) to be considered for ease in removal. 8.5. Temporary conical strainers are to be placed with the cone pointing opposite to the direction of flow. 9. Pressure Drop across a Strainer / Mesh Number

  • How to Select a Strainer Flow Control

    Any flow rate over 150 GPM will most likely require a basket strainer because of pressure drop considerations. Strainers are usually sized so that their start up pressure drop is no greater than 2 PSI, with a line velocity not to exceed 8 FPS. On a per size basis, basket strainers exhibit less pressure loss than Y-Strainers.

  • STR995-1 Pressure Drop Data Basket

    Strainer Size: 3" a) Using FIGURE 1 the pressure drop is determined to be 0.4 psid using the standard screen Filtration: 100 mesh lined 1/8" perf. b) Looking at the replacement screen data sheet, we find that the % open area of 100 mesh is 30%

  • Types 50-P 51-P Temporary Strainers - Startup Strainers ...

    50-p cone strainer pressure drop charts 40 mesh 60 mesh 80 mesh 30 1.00 1.32 1.53 1.62 270 1.30 1.61 1.83 2.00 385 1.44 1.76 2.00 2.20 500 1.58 1.92 2.13 2.41 1000 1.66 2.22 2.41 2.63 2000 1.86 2.41 2.72 2.91 viscosity p e (ssu) rforated perforated with wire cloth 1/8" dia. holes for water use 30 ssu correction factors

  • CONACO

    pressure drop calculation software. Element surfaces are designed to meet the process requirements. @ Different designs are developed to meet the required operating conditipns and filtration degree. Cone Type Strainers 2".SS

  • Strainers - Y-strainer, basket, pot type Flosteer strainers

    Strainers ("Y" Type) Flosteer bolted cover “Y” Type strainer has low pressure drop due to higher flow area through screen. Flosteer “Y” Strainer mechanically removing solids from flowing liquids, Air, Steam or gases by means of a perforated or wire mesh straining element.

  • Inko Engineering Supplies Pte Ltd

    Since the viscosity is 200 SSU, the corrected pressure drop = I .30 X I .30 2.69 psi Since there is an extra 40 mesh lined wire mesh, corrected pressure drop = 1.61 x 1.30 = 2.09 psi Sizing Y-strainer Correction fnetor: For liquids moro viseous than water or whom wire cloth Iinor added. pressure droo in charts by PerfMated w'Wire Cloth Attacnea ...

  • Temporary Cone Strainer, Start Up or Commissioning Witches ...

    Temporary cone strainers can be supplied with mesh lining on the inside or outside of the cone depending upon flow direction. Special reinforcing rings and supports can be installed to maintain integrity of the cone or basket for heavy load applications where the differential pressure will exceed 20-30 psi.

  • Pressure Drop Across Coarse Strainers - Industrial ...

    Aug 11, 2009  Pressure Drop Across Coarse Strainers - posted in Industrial Professionals: Hello everyone,I'm working on a project where it has been proposed to install a coarse strainer on the suction side of a pump, to prevent large objects damaging the pump. The strainer is a flat plate, with as much 10mm holes as possible punched into it. I'd like to calculate the pressure drop across it, and am ...

  • The influence of strainer types on the flow and droplet ...

    pressure drift reduction flat-fan nozzles, and from 1.5 to 2 bar for the wide pressure range flat-fan nozzles (Agrotop GmbH, 2010). 2.2. Nozzle strainers This study used 2 standard cylindrical strainers with 50-mesh screens of a different type each, 2 screen-type cylindrical strainers

  • Fabricated Strainer Fabricated Strainer Au Tee ...

    Fabricated Strainers Temporary Cone Strainers; Temporary Basket Strainers; Tee Strainers; Orifice Plates; Spectacle Blinds; Flat Strainers; Fiberglass Reinforced Plastic Strainers; Special Design Strainers; 304LSS, LTC.S, Special Alloys T Strainers; Materials for Replacement Screens; Pressure Drop for Fabricated Strainers

  • An article on Strainers used in piping Industry – What Is ...

    Temporary Strainers. Cone type; Truncated Cone type; Design Codes for Strainers. Strainers or filters are normally designed following the below mentioned International Standards: ANSI B 16.34; PED 97/23/EC: Pressure equipment design; BPV: ASME Boiler Pressure vessel code, Section-VIII Div.1; Materials of Construction of Strainers: Body. Forged

  • Temporary Strainers - Dannenbaum LLC Dannenbaum LLC

    Conical strainers are shaped like a cone, or witch’s hat. Conical strainers can catch particles down to .001 inch in diameter. Cone strainers have little pressure drop, and can be removed after startup, and the debris is evacuated. The sizing of Conical strainers is important to ensure the strainer screen can block particles that could damage ...